ASB Trade › Guides › Aluminium ladder or stepladder: which height and type to choose

Aluminium ladder or stepladder: which height and type to choose

For work in a room, choose a stepladder with its platform about 2 m below the point you need to reach. For a wall or a facade, choose a leaning or sectional ladder. Below are a task-to-type table and an explanation of names such as 5+1 and 3×10.

Types of ladder and the job each one suits

A stepladder stands on its own and needs no wall. It has two sides, or one side with a platform on top. Use it indoors: painting, filling, fitting a lamp or curtain rail, wiring.

A single (leaning) ladder rests against a wall at one end. It is light, and it suits jobs higher than a stepladder reaches where there is something to lean on.

A two- or three-section ladder has two or three parts that slide out or join together. It is for facades, roofs and tall walls.

A multi-purpose (transformer) ladder folds into a stepladder, a leaning ladder and other positions. One ladder replaces several, but it is heavier. A support ladder and a scaffold ladder have two sides and a standing platform; they are set up for longer work in one place.

How to work out the height you need

Working height is how high a person standing on the top platform can reach. It is roughly the height to the platform plus about 2 m for your own reach with an arm raised. For a 3 m ceiling you need a platform at about 1 m.

Choose one step more than the minimum. Then you will not have to work from the very top step, which is dangerous. For a 2.7 m ceiling, a stepladder with a platform at 0.86 to 0.88 m is enough. For a 3 m ceiling, look for a platform at 1.08 to 1.31 m. For 3.5 m, about 1.5 m.

A leaning ladder is measured differently. Its length must be greater than the height of the job: the top must rest above the edge of the wall or gutter, and when climbing onto a roof the ladder must stick out above the edge. Check the extended length on the product page.

JobTypeExample from the shop
Painting, lamp or curtain rail in a room, ceiling 2.7 to 3 mStepladder, 4 to 5 stepsNovaya Vysota 2×4 (working height 2.88 m), Premier 5+1 (3.31 m)
Ceiling 3.5 m, working with tools on the platformStepladder, 6 to 7 steps, with organiserNovaya Vysota reinforced 1×6 with organiser (3.29 m), Premier 7+1 (3.74 m)
Wall, window, entrance, loggiaSingle leaning ladderNovaya Vysota 1×9
Facade, fence, roof, tall wallTwo- or three-sectionNovaya Vysota 2×12, 3×10
Mixed jobs at home and in the garageMulti-purposeNovaya Vysota 4×5

What the numbers in the name mean, and the load rating

On a Premier stepladder, "5+1" means five steps and a top platform. On a double-sided stepladder, "2×5" means two sides of 5 steps. "1×7" is one section of 7 steps. "2×12" and "3×10" are two sections of 12 steps and three sections of 10 steps. "4×5" is four sections of 5 steps.

The load is given on the product pages: 225 kg for the reinforced Novaya Vysota ladders, 180 kg for the double-sided aluminium stepladders, and 150 kg for most of the rest. For Premier stepladders, read the load on the label. Ladders made to EN 131 are rated for a total load of up to 150 kg. That total includes the person, the tools and the material, not only the person.

If you climb with a heavy tool, add its weight to yours and check that the sum is below the load on the label.

Models in the shop

For work indoors: Premier 3+1, 5+1, 7+1 and 9+1 (the 9+1 is 2.68 m overall, has a working height of 4.17 m and weighs 13.8 kg). The steps are non-slip plastic, and the folded stepladder is carried by a handle. The reinforced Novaya Vysota ladders with an organiser, from 3 to 7 steps, carry 225 kg, and the organiser keeps tools and fixings to hand.

The light leaning ladders Novaya Vysota 1×7, 1×9 and 1×11 weigh 2.7, 3.4 and 4.1 kg. For high work there are two-section 2×9, 2×11, 2×12 and three-section 3×7, 3×9, 3×10, 3×11, 3×13 ladders. The multi-purpose 4×3, 4×4 and 4×5 come with or without a platform. The scaffold ladder 2×8 has its platform at 2.12 m.

Using a ladder safely

Set the ladder on level, firm ground and open a stepladder fully. Check the section locks before you climb.

Set a leaning ladder at about 75 degrees: for every 4 m of height, move the foot about 1 m from the wall. The top must rest on a solid surface.

Keep three points of contact: two hands and a foot, or two feet and a hand. Do not stand on the top steps and do not lean sideways beyond your body width. Carry tools in a bag or on the organiser, not in your hands.

Aluminium conducts electricity. Do not set the ladder near live wires and do not work on wiring with the power on. Leave work on the distribution board and the mains to a licensed electrician.

Related products

Frequently asked questions

Which stepladder do I need for a 2.7 to 3 m ceiling?

One with a platform at 0.9 to 1.3 m. For example, Novaya Vysota 2×4 for 2.7 m, or the reinforced 1×5 with organiser or Premier 5+1 for 3 m. Take one step more than the minimum.

What does 2×12 or 3×10 mean in the name?

The first number is the number of sections, the second is the steps in each section. 2×12 is two sections of 12 steps.

What load does an aluminium ladder carry?

From 150 to 225 kg according to the product pages; for Premier, read the label. The load includes the weight of the person and the tools.

At what angle should I set a leaning ladder?

About 75 degrees. For 4 m of height, move the foot 1 m from the wall.

Categories