Apartment distribution board: groups, breakers, size

First a plan of lines, then breakers matched to cable cross-section, then the enclosure size in modules. What to buy and what is the electrician's job.

In brief

Start the board with a plan of lines: lighting, sockets, kitchen, bathroom and heavy appliances each go on their own breaker. The breaker rating is matched to the cable cross-section. A 30 mA RCD goes on the sockets and wet areas. Count the enclosure size in modules and add 20–30 % spare room.

You can choose and buy the parts in advance, but the assembly and the connection to the incoming supply belong to a licensed electrician.

Step 1. Split the flat into groups

The more separate lines, the easier it is to find a fault and the less often the whole flat loses power. A typical set for a flat: lighting (one or two groups), room sockets (one group for one or two rooms), kitchen, oven or hob, washing machine, water heater, air conditioner, bathroom sockets.

Heavy appliances such as the oven, hob, water heater and air conditioner do not share a line: each gets its own. Kitchen sockets that feed the kettle, microwave and other appliances are also kept apart from the room sockets.

Draw a plan: on a sketch of the rooms mark every socket, light and appliance, then group them into lines. From the plan the electrician quickly estimates cable lengths, load and the number of breakers, and does not have to guess.

If you plan underfloor heating, an electric cooker or an air conditioner later, provide separate lines and free space in the board in advance: reworking a finished renovation costs much more.

Step 2. Breaker rating by cable

The breaker protects the cable, so the conductor cross-section decides its rating. Guide values for copper: lighting on 1.5 mm² — 10 A; sockets on 2.5 mm² — 16 A; air conditioner, water heater, oven on 2.5–4 mm² — 16–25 A; hob on 4–6 mm² — 25–32 A.

These are guides: the final figure depends on the appliance power, the length of the line and the way it is laid, and the electrician sets it. See our articles on choosing a breaker and on cable for sockets and lighting.

If the cable in the walls is already laid, ask the electrician what its cross-section is, and do not change a breaker rating by eye. A breaker larger than it should be stops protecting the wire.

The main breaker and the flat's power

The incoming breaker is two-pole and matched to the permitted connection power. Current is roughly power divided by 230 V: for example, 25 A corresponds to about 5.7 kW. Ask the company that supplies your electricity what power your connection allows, and do not pick a main breaker above that value for extra margin.

The sum of the group ratings can exceed the main rating, because not everything runs at once. Still, think about which appliances you switch on together, for example the oven and the water heater.

If you are unsure what your supply is, look at the meter plate and at the breaker on the landing; the electrician will confirm the exact rating.

RCDs and RCBOs

A 30 mA RCD protects against leakage current. It goes on the sockets, kitchen, bathroom, water heater and washing machine, with a breaker ahead of it. Alternatively, important lines get RCBOs. How they differ and what to ask the electrician is in the article on RCD versus RCBO.

Lighting is often left without an RCD or put on its own, so that a leak in the sockets does not turn the lights off.

Sockets in the bathroom and for the washing machine are usually put on a separate line with a 30 mA RCD, so that a leak there does not cut power to the rest of the flat.

How many modules and which enclosure

One module is 17.5 mm wide. A single-pole breaker takes 1 module, a two-pole breaker and a two-pole RCD take 2 each. Example: the main breaker 2 modules, two RCDs 4 modules, eight single-pole breakers 8 modules. That is 14; with a 30 % reserve about 18, so you need a 24-module enclosure.

Enclosures are surface-mounted or flush-mounted into a niche. Inside you need a DIN rail, bars for neutral and earth, and line labels; the electrician will tell you what to take for the specific enclosure. Leave spare room for future lines, because adding a breaker to a full board often means replacing the enclosure.

Arrange the devices in order: the main breaker at the top, below it the RCDs and line breakers, with every line labelled. A label saves hours when you look for a fault years later.

What the electrician does and what you do

You list the appliances, think over where the sockets go and choose the parts. The electrician checks the cable sizes, calculates the load, assembles the board and connects it to the supply and the lines. After installation he tests insulation and the RCD operation. He works to local rules.

Do not connect the board yourself or add lines to a live board without an electrician: there is always voltage at the incoming terminals.

Before the work starts, agree the scheme with the electrician in writing: list the lines, ratings and the place of the board. This cuts down on rework and misunderstandings.

What the catalog offers

Enclosures: the plastic Almera for 9 modules, about 13.1 ₾, and for 12 modules, about 15.9 ₾. Larger ARS boards, surface and flush, are also available; check the number of places on the product page.

LEGRAND XS3 breakers, 4.5 kA: B10 for lighting, about 6.4 ₾; B16 for sockets, about 6.4 ₾; B20, about 6.4 ₾; B32, about 7.9 ₾. A two-pole Xkoren XKN6 C 40 A, 6 kA main breaker is about 15.2 ₾. The Xkoren XKR6 RCD, 2 poles, 30 mA, 40 A, is about 34.5 ₾; the name does not give type AC or A, so check the marking.

Prices are as of 18.11.2026; see the product page for the current price. Electrical goods and lamps are sold by the pack: the price is per unit, see the product page for the number of units in a pack.

Checklist before buying

Make a list of lines with ratings and cable sizes. Count the modules of all devices and add 20–30 % spare. Choose the enclosure: surface or flush. Take a two-pole main breaker, line breakers by rating, and a 30 mA RCD or RCBOs for the wet lines.

Ask the electrician what else is needed: a DIN rail, bars for neutral and earth, line labels, cable of the right size. Show the list to the electrician before buying: he will correct the ratings, and you will not have to return devices.

Related products

Frequently asked questions

How many breakers does a flat need?

Usually 8–12 lines: lighting, room sockets, kitchen, oven or hob, washing machine, water heater, air conditioner, bathroom, plus the main breaker. The exact number depends on the plan of the flat and the appliances.

Which enclosure should I take for the board?

Add up the modules of all devices and add 20–30 % spare. For a small flat an enclosure of 12–24 modules is usually enough.

Is a main breaker needed?

Yes, a common two-pole breaker goes at the input: it disconnects the whole flat and limits the power drawn. Its rating follows the permitted connection power.

Can I assemble the board myself?

You can choose and buy the parts, but the assembly, connection to the supply and testing must be done by a licensed electrician following local rules.

Do I need spare room in the board?

Yes. Leave free modules for future lines, such as an air conditioner or underfloor heating: adding devices to a full enclosure is awkward.