ASB Trade › Guides › Home EV charger: portable or wallbox, kW, connectors

Home EV charger: portable or wallbox, kW, connectors

A home charger has to match three things: the car's on-board charger, your supply (single-phase or three-phase) and wiring checked by a licensed electrician. More kilowatts on the box do not help if one of the three is the limit.

In brief

Charging speed is set by the weakest of three links: the charger, the home supply and the car's on-board charger. A 22 kW box will not charge a car faster than the car accepts, and a three-phase charger needs a three-phase supply.

In practice most homes end up with 3.7 or 7 kW on a single-phase supply, or 11 kW where the building has three phases and the car accepts it. A portable charger is the flexible option; a wall-mounted unit on its own protected line is the permanent one. Whatever you choose, the line, the protection and the connection are for a licensed electrician to design and check.

What decides the charging speed

Power in kilowatts is voltage times current. On a 230 V single-phase supply, 16 A gives about 3.7 kW and 32 A about 7.4 kW. On a 400 V three-phase supply, 16 A gives about 11 kW and 32 A about 22 kW.

Then check the car: its manual or spec sheet gives the maximum AC charging power. Many cars accept 7 or 11 kW, and only some accept 22 kW. As a rough estimate, a 60 kWh battery goes from empty to full in about 16 hours at 3.7 kW and about 8 to 9 hours at 7 kW, and a little longer in practice because of losses.

For overnight charging at home 7 kW is usually plenty. Faster home charging pays off if you drive long distances every day or two cars share one charger.

Single-phase or three-phase supply

Look at your main breaker and meter. A single-phase supply has a one-pole or two-pole main breaker, a three-phase supply a three-pole or four-pole one. In apartments the supply is often single-phase, which means about 7.4 kW at best. Chargers of 11 and 22 kW need a three-phase connection and a car that can use it.

There is a second limit: the total power your connection may draw, set by your contract with the electricity distributor and by the main breaker. A 7 kW charger running next to an oven, a kettle and an air conditioner can overload it. Ask the electrician to check the margin. Many chargers also let you set a lower charging current.

Portable charger or wallbox

A portable charger is a cable with a control box and a plug. You keep it in the boot and charge wherever a suitable outlet exists. It is a flexible start and fits a rented flat or a second location. The plug matters: a household Schuko socket is made for ordinary loads, while a car draws a high current for hours, so have an electrician check that socket, its wiring and its breaker, or install a proper industrial CEE socket for the purpose.

A wall-mounted charger is fixed, normally on its own circuit with its own breaker and RCD. It is the better choice if you park in the same place every night: it is neater, can offer RFID access or app control, and the line is designed for continuous load. Some units have a fixed cable, others a Type 2 socket for your own cable.

Connectors: Type 2, Type 1 and adapters

In Europe the standard AC connector is Type 2, and every charger in our catalog uses it. Many cars in Georgia are imported from the United States and have a Type 1 (J1772) inlet; some US Teslas have the NACS port, and cars made for the Chinese market may use a GB/T inlet. Look at the inlet on your car before you buy anything.

For a Type 1 car the simple solution is a charger with a Type 2 socket plus a Type 2 to Type 1 cable. Type 1 is single-phase only, so such a car is limited to about 7.4 kW at 32 A whatever the charger offers. US cars are built for 240 V; as a rule they accept 230 V, but confirm it in the manual. For a NACS car adapters exist, but compatibility depends on the model and year, so ask the adapter maker and use only certified products. An adapter changes the shape of the plug, not the car's charging limit.

Fast DC charging (CCS, CHAdeMO) is a different system and is not for the home.

Cable, breaker and RCD

Charging cables Type 2 to Type 2 come rated for 16 A (11 kW on three phases) or 32 A (22 kW on three phases). A cable rated for 16 A limits the current to 16 A, so its rating must match the charger and the car.

Protection is a dedicated breaker for the charger and a residual current device (RCD). The usual requirement for EV charging points, set out in IEC 60364-7-722, is a separate RCD for each charging point, at least Type A, together with protection against DC leakage of 6 mA: either built into the charger or provided by a Type B RCD. An ordinary Type AC RCD is not suitable. Whether your charger has built-in DC detection is in its manual; the electrician selects the matching RCD.

What the electrician must check

Before installation a licensed electrician should check: the type of supply and the permitted power; the state of the distribution board and the earthing, because a charger on poor earthing is dangerous; the cable cross-section for the length and the way it is laid; the breaker and RCD ratings; and, for an outdoor charger, its protection class (IP).

Ask for a separate line from the board, not a branch off an existing socket circuit. Do not connect a charger to the fixed wiring yourself: this is work for a licensed electrician.

HIMS chargers in the catalog

The shop carries HIMS chargers: for most items (chargers, cables, V2L adapters) the price is shown on the product page, for example the portable HCTK-3-G, 3.7 kW, at 658 ₾ and the wall-mounted HCDK-22-B, 22 kW, at 2,071 ₾; for the rest the price is on request. Chargers are brought in to order: we agree the lead time after the order is placed, and payment is by prepayment only. Installation by a partner is available on request: write to us with your car model and the type of your supply and we will say what fits. Prices as of 18.11.2026.

Portable, Type 2: HCTK-3-G (3.7 kW, Schuko plug, 5 m cable), HCTK-7-PS (7 kW, CEE 32 A plug, Wi-Fi), HCTK-11-PS (11 kW, three-phase, Wi-Fi), HCTK-11-PS-S (11 kW, RFID, OCPP) and HCTK-22-G (22 kW, three-phase, IP66). Wall-mounted: HEVC-22 (22 kW, Type 2 socket, RFID, Wi-Fi) and HCDK-22-B (22 kW, tethered Type 2 cable, RFID, OCPP). Cables: EMEF-11T2 (Type 2 to Type 2, 11 kW, 16 A, 5 m) and EMEF-22T2 (22 kW, 32 A, 5 m).

A 22 kW charger on a single-phase supply, or with a car that takes 7 kW, will still deliver only what the supply and the car allow.

Related products

Frequently asked questions

Can I charge from an ordinary socket?

Some portable chargers come with a Schuko plug, and occasional charging is possible if the socket, wiring and breaker are in good condition and an electrician has checked them. For daily charging a dedicated line and a wall-mounted charger are safer.

Do I need a three-phase supply for 11 or 22 kW?

Yes. Three-phase chargers need a three-phase connection, and the car's on-board charger must accept three-phase AC. Check both before you buy.

Will a 22 kW charger charge my car faster than a 7 kW one?

Only if the car's on-board charger accepts more than 7 kW and the supply can deliver it. Many cars accept 7 or 11 kW, so the extra capacity of a 22 kW box often goes unused.

My car is a US import with a Type 1 inlet. Can I use these chargers?

Yes, with a charger that has a Type 2 socket and a Type 2 to Type 1 cable. The car stays limited to single-phase charging, about 7.4 kW at most. For NACS cars check adapter compatibility for your model and year.

How much does a home charger cost?

For most HIMS items (chargers, cables, V2L adapters) the price is shown on the product page: from 112 ₾ for a V2L adapter to 2,303 ₾ for a 22 kW portable charger; for the rest the price is on request. Chargers are made to order: we agree the lead time after the order is placed, and payment is by prepayment only. Installation by a partner is available on request. Write to us with your car model and supply type.

Categories