Stabiliser and UPS for a gas boiler: which one to choose
A stabiliser evens out the voltage, but it does nothing in a power cut. To keep the boiler heating the house without mains power, you need an inverter or UPS with a battery and a pure sine wave output. Choose the power from the boiler's rating plate: a wall-hung boiler usually draws about 100-200 W.
Why a gas boiler needs protection from the mains
A modern wall-hung boiler is more than a burner. It has a control board and a circulation pump, and both run on mains power. Voltage spikes and dips are bad for the board and the pump and can damage them.
The second problem is a power cut. Without electricity the board and pump stop, so the boiler shuts down even though there is gas in the pipe. The house cools, and in hard frost the heating system itself can suffer.
Two different devices solve these two problems. A stabiliser protects against voltage swings. An inverter or a UPS with a battery keeps things running in a power cut.
Stabiliser or UPS: what is the difference
A stabiliser takes voltage from the mains and evens it out. If there is no mains at all, it has nothing to even out, and the boiler stops.
A UPS (uninterruptible power supply) and an inverter store energy in a battery. When the mains fails, they switch to the battery and give the socket normal 230 V. An inverter is the same idea, but its battery is connected separately, so you can choose any capacity.
| Stabiliser | Inverter or UPS with a battery | |
|---|---|---|
| Voltage spikes and dips | Evens them out | Protects against spikes (per the POWERCOM model descriptions) |
| Power cut | Does not work | The boiler keeps running from the battery |
| What matters for a boiler | Input voltage range, accuracy, speed | Pure sine wave, power, battery capacity |
| Battery needed | No | Yes, an inverter uses an external one |
Which stabiliser a boiler needs
First find the boiler's power. It is printed on the rating plate, the label on the casing. A wall-hung gas boiler usually draws about 100-200 W. If the plate shows VA instead of W, ask the seller or an installer how to convert it. Always compare watts with watts.
Choose a stabiliser with a reserve of power. The boiler pump has a motor, and a motor draws more than its rated power when it starts. The Defender stabiliser descriptions say the same: equipment with an electric motor needs a reserve.
There are three main types of stabiliser. A relay stabiliser changes the voltage in steps and clicks slightly as it switches. A servo (electromechanical) stabiliser uses a motor and works smoothly and accurately, but more slowly. An electronic (thyristor) stabiliser has no moving parts and is fast and quiet.
For a boiler, look at three things: the input voltage range (it must cover the real dips in your network), the accuracy of the output and the speed of response. The descriptions of the Defender models in the shop do not state the type or the input range, so ask us before you buy.
An inverter for a boiler: pure sine wave and run time
Mains voltage is a sine wave, a smooth curve. An inverter can produce a true (pure) sine wave or an approximate, stepped one. A pump motor and boiler electronics need a pure sine wave. On a stepped wave the pump may hum and run hot, and the boiler board may misbehave. If the boiler manual says otherwise, follow the manual.
Check this in the specification. If the wave shape is not stated, do not assume the device suits a boiler. The POWERCOM INF-800AP and INF-1100AP are listed with a simulated sine wave, so they are not for boilers.
Run time is worked out with a formula: hours ≈ battery voltage (V) × capacity (Ah) × 0.7 ÷ load (W). The factor 0.7 allows for losses in the inverter and for the fact that a battery must not be drained to zero.
Example. A 24 V, 100 Ah battery and a 150 W boiler. 24 × 100 × 0.7 = 1680 Wh. Divide by 150 W and you get about 11 hours. If lights and a router run from the same battery, add their load and the time drops. The real time depends on the condition of the battery, so allow a margin.
Which models the shop has and how to connect them
Defender stabilisers: the ASF 1000D at 600 W with one outlet, the ASF 1500D at 900 W and ASF 2000D at 1200 W with two outlets, and the ASF 3000D at 1800 W with a terminal connection. For a single wall-hung boiler the smallest model has enough power. The others make sense if other equipment is on the same stabiliser.
POWERCOM inverters with a pure sine wave: the INF-1500AP at 1500VA / 1050W and the INF-3000AP at 3000VA / 1800W. Both are Offline/Standby types that use an external battery. The INF-1500AP model name states a 24 V 100 Ah battery, and the INF-3000AP states 36 V 65 Ah. The input voltage is 208-240 V and there is a USB port for monitoring. The battery is not included. When the unit switches to the battery, power may drop out for a moment and the boiler may restart.
A phase-dependent boiler tells the live wire from the neutral, so take this into account when connecting it to a stabiliser or inverter and read the boiler manual. The boiler must be earthed, and the earth connection must not be lost on the way through a stabiliser or inverter.
Wiring the boiler through terminals, a layout with a stabiliser and an inverter together, and anything to do with the gas side must be done by a specialist. Do not touch gas equipment without a licence. If you are not sure, send us the boiler model and we will help you choose.
Related products
- Defender ASF 1000D automatic voltage regulator, 600 W, metal body, 1 outlet
- Defender ASF 1500D automatic voltage regulator, 900 W, metal body, 2 outlets
- Defender ASF 2000D automatic voltage regulator, 1200 W, metal body, 2 outlets
- Defender ASF 3000D automatic voltage regulator, 1800 W, metal body, terminal block
- POWERCOM INF-1500AP inverter, 1500VA/1050W, Offline/Standby, sine wave
- POWERCOM INF-3000AP inverter, 3000VA/1800W, Offline/Standby, sine wave
Frequently asked questions
Does a gas boiler need a stabiliser?
If the mains voltage jumps and dips, yes: the control board and pump do not cope well with such swings. Take the power from the boiler's rating plate, usually about 100-200 W, plus a reserve for the pump start-up.
Can I connect a boiler to an ordinary computer UPS?
Only if the UPS gives a pure sine wave on battery. The descriptions of the POWERCOM RPT models do not state the wave shape, so we do not offer them for boilers. Inverters with a pure sine wave suit a boiler, for example the POWERCOM INF-1500AP and INF-3000AP.
How many hours will the battery last?
Hours ≈ voltage (V) × capacity (Ah) × 0.7 ÷ load (W). For a 24 V, 100 Ah battery and a 150 W boiler that is about 11 hours.
Can I connect a stabiliser or inverter to the boiler myself?
You can plug a stabiliser into a socket, but wiring through terminals and handling phase and earthing is a job for an electrician. Only a licensed specialist works on the gas side of a boiler.