ASB Trade › Network & power › UPS and inverters

UPS and inverters

23 items · APC, POWERCOM, SUMRY, Ultracell

Uninterruptible power supplies from POWERCOM and APC and inverters from POWERCOM and SUMRY: from compact 600–700 VA units for a router and a computer to 6 and 10 kW online models for a server room and equipment that must not switch off.

A UPS keeps equipment running when the mains fails and gives time to save work or wait for the power to return. The rating in the name has two numbers: volt-amperes (VA) and watts (W). It is the watts that are compared with the load: the RPT-1000A gives 600 W, the RPT-1500AP 900 W. The total wattage of the connected devices is taken with a margin of about a third.

Also searched as: UPS, uninterruptible power supply, battery backup, inverter, power backup

Guides

Which UPS to choose: offline, line-interactive or online

The UPS type is stated in the model name. An offline unit such as the POWERCOM WOW-700U passes mains voltage straight through and switches to the battery when the power fails: that is enough for a router, a till or a single computer. The line-interactive RPT series, from the RPT-600A to the RPT-1500AP, also corrects the voltage without going to battery, so it is chosen where the mains is unstable.

The online MAC series, from the MAC-1500 to the MAC-10K, feeds the load through double conversion all the time, and there is no switchover when the mains fails. Such a UPS is installed on servers, storage systems, medical and other equipment that is sensitive to power quality. MAC models have an automatic and a manual bypass, so the load can be moved to the mains during maintenance.

An inverter for the home: pure or approximated sine wave

An inverter differs from an ordinary UPS in that it is built for long runs from an external battery: the backup time depends on the capacity of the battery connected to it. The name states the output waveform. The POWERCOM INF-800AP and INF-1100AP give an approximated sine wave, the INF-1500AP and INF-3000AP a pure one.

A pure sine wave is needed by equipment with motors and pumps: a gas boiler, a circulation pump, a refrigerator. For lighting, a router and a television an approximated wave is usually enough. SUMRY inverters state the battery voltage in the name: the Tron Duo runs from 12 V, the Tron Uno HTU-2005 from 24 V, so the batteries are chosen to match that figure.

Frequently asked questions

What is the difference between VA and W in a UPS rating?

VA is apparent power, W is real power, the part the equipment actually draws. It is the watts that are compared with the load: the POWERCOM RPT-800A, for example, is rated 800 VA and 480 W, so the total load should stay well below 480 W.

Which UPS is needed for a router and a computer?

For a router and one computer with a monitor a line-interactive model of 600–1000 VA is the usual choice, such as the RPT-600A or RPT-1000A. For a closer figure add up the watts on the equipment's power supplies and leave a margin of about a third.

Is a UPS suitable for a gas boiler?

A boiler and a circulation pump need a pure sine wave and a long backup time. An inverter with an external battery and a pure sine wave, such as the POWERCOM INF-1500AP, or an online UPS of the MAC series is used for this. Check the power requirements in the boiler's manual.

What is a bypass in a UPS?

A bypass is a line that feeds the load straight from the mains. The automatic bypass comes on when the UPS is overloaded or faulty, and a manual bypass, as on the MAC series, lets the unit be serviced without switching the equipment off.