Wired or wireless fire alarm for business in Georgia
Wireless is better for a working, already fitted-out site; wired addressable is better for new construction and large buildings. A small site can do with a conventional panel, and passing inspection depends on the specific site.
In short: what to choose
Wireless suits a business that is already running and fitted out: no cable runs, no chasing walls, no stopping work. Wired, usually addressable, suits new construction, large buildings and projects planned to grow.
We compare on six points: cabling work, disruption of a working business, conventional versus addressable panels, large buildings, maintenance and battery upkeep. The examples are picked from specifications and catalog prices, not lab tests. Prices as of 18.11.2026; the current price is on the product page.
| Point | Wired system | Wireless system |
|---|---|---|
| Cabling work | Fire cable to every device | No cable, devices are fixed in place |
| Working business | Ceilings and finishes opened, possible pauses | Minimal disruption, the site keeps working |
| Panel | Conventional (zones) or addressable (each device) | Hub, or gateway to an addressable panel |
| Large building | Standard: loops, modules, repeaters | Radio coverage must be calculated, often mixed |
| Maintenance | Check cable, detectors and panel | Check devices and radio link |
| Batteries | Panel backup batteries only | Battery in every device, replaced on schedule |
Cabling work and a working business
A wired system needs fire cable from the panel to every detector, sounder and call point. In a new building it is laid together with the other low-voltage lines, which is easy to organise. In an operating shop, restaurant or office you have to open ceilings and cable trunking, sometimes pause trading, and restore the finish afterwards.
A wireless system avoids that: the detector is fixed to the ceiling, added to the hub or gateway and tested. For example, the Dahua HY-SA30A (50.60 ₾) is a standalone smoke alarm with a built-in battery, so installation is just fixing it to the ceiling. The Dahua HY-L121 wireless manual call point (126.56 ₾) joins an addressable system through the WG-1037 gateway without cable, and the manufacturer names already refurbished and historic buildings as its use.
Conventional and addressable panels
A conventional panel groups detectors into zones: it shows the zone, not the exact detector. For a small site that is fine. The Dahua HY-C102-4 (485.16 ₾) has four zones of 32 devices each and suits shops, offices, workshops and warehouses; 6 and 8 zone versions exist. The Teletek MAG belongs to the same conventional class.
An addressable panel sees each device separately and shows exactly which detector went off. In a large building that saves time and eases maintenance. Dahua HY-1022R (1546.89 ₾): one loop for up to 254 devices, a 4.3 inch display, a log of 2048 events. Teletek SIMPO (1623.25 ₾): one loop expandable to two, 48 zones, up to 250 detectors per loop. Teletek SIMPO X (2349.44 ₾) adds a LAN module and a Georgian menu.
| Model | Type | Price, ₾ |
|---|---|---|
| Dahua HY-C102-4 | Conventional panel, 4 zones | 485.16 |
| Dahua HY-1022R | Addressable panel, 1 loop, 254 devices | 1,546.89 |
| Teletek SIMPO | Addressable panel, 48 zones | 1,623.25 |
| Teletek SIMPO X | Addressable panel, 48 zones, LAN | 2,349.44 |
| Dahua HY-L121 + WG-1037 gateway | Wireless manual call point + gateway | 126.56 + 182.81 |
| Ajax FireProtect 2 SB (Heat/Smoke/CO) | Wireless detector, battery up to 10 years | 325.18 |
| Ajax EN54 FireProtect (Smoke/Sounder) | Smoke detector with sounder, EN54 line | 216.63 |
| Dahua HY-SA30A | Standalone smoke alarm | 50.60 |
Large buildings
In a large building you need addressing, spare loop capacity and a robust line. A wired addressable system handles this in the standard way: add loops, modules and repeaters. The Teletek iRIS8 scales to 8 loops and 200 zones, and Dahua HY-1022R panels can be cascaded, up to 128 over RS-485.
A wireless system on a big site needs thought about radio coverage: walls, floors and distances affect the link, and sometimes a repeater is added. For Ajax the manufacturer states Jeweller range up to 1700 m in open space for the FireProtect 2 SB and ManualCallPoint, but inside a building the real range is lower. That is why on a large site we survey first and calculate afterwards. The Dahua WG-1037 (182.81 ₾) links wireless devices to an addressable panel.
Maintenance and battery upkeep
Wired detectors are powered from the loop, so the detectors themselves hold no batteries. Backup power sits in the panel: two 12 V 2.5 Ah lead-acid batteries in the Dahua HY-C102-4, two 12 V 5 Ah in the HY-1022R. Those are what you check and eventually replace.
In a wireless system every device has a battery. Manufacturer figures: Ajax FireProtect 2 SB (325.18 ₾) has non-removable lithium batteries rated up to 10 years, Ajax FireProtect (177.36 ₾) runs up to 4 years, Ajax ManualCallPoint (175.64 ₾) up to 7 years, Dahua HY-L121 about 5 years. Real life depends on conditions, so a maintenance plan needs scheduled checks and a replacement log. In the Ajax EN54 line, backup power comes as the Internal Battery (24 h) at 176.03 ₾; check compatibility with your device before ordering.
Inspection and installation
The fire inspection decides for each specific site. In our practice, systems on Ajax have passed inspection, both the EN54 line and regular FireProtect detectors, including at an arms store and a shooting range. This is experience, not a guarantee: the final decision belongs to the inspection. According to the manufacturer, the Fire Hub of the Ajax EN54 line is certified to EN 54, while regular FireProtect works with an Ajax hub and combines security and fire in one app.
We install in Tbilisi and the surrounding area, and in other cities by project. A specialist visit costs 75 ₾ and is credited to your bill. Send the site type, area and address in the chat.
Related products
- Dahua HY-C102-4 conventional fire alarm panel, 4 zones, EN54-2/4
- Dahua HY-1022R addressable fire alarm panel, 1 loop, 254 devices, printer option
- Teletek SIMPO addressable fire control panel, 1 loop (up to 2), 48 zones
- Teletek SIMPO X addressable fire control panel, 1 loop (up to 2), 48 zones, LAN
- Dahua HY-L121 wireless LoRa manual call point, 1500 m, 5-year battery
- Dahua WG-1037 addressable LoRa gateway, up to 32 wireless devices
- Ajax FireProtect 2 SB (Heat/Smoke/CO) Jeweller wireless smoke, heat and CO detector
- Ajax EN54 FireProtect (Smoke/Sounder) smoke detector with sounder, white
- Ajax ManualCallPoint Jeweller wireless manual call point, red
- Ajax EN54 Internal Battery (24h)
Fire alarm installation — Specialist visit 75 ₾, credited to your bill.
Frequently asked questions
What is better for a working shop: wired or wireless?
Usually wireless: no cable and no opening of finishes, and the shop keeps trading. The final choice depends on the size of the site and radio coverage.
When do I need an addressable panel?
In a large building where you need to know exactly which detector went off. A small site often does with a conventional panel, for example the Dahua HY-C102-4 (485.16 ₾).
How long does a wireless detector battery last?
Manufacturer figures: Ajax FireProtect 2 SB up to 10 years, Ajax FireProtect up to 4 years, Dahua HY-L121 about 5 years. Real life depends on conditions.
Will the fire inspection accept a wireless system?
In our practice, systems on Ajax have passed inspection, including at an arms store and a shooting range. This is not a guarantee: the inspection decides for each specific site.
Do you do installation?
Yes, in Tbilisi and the surrounding area, and in other cities by project. The specialist visit of 75 ₾ is credited to your bill.