ASB Trade › Fire safety › Gas detectors
Gas detectors
16 items · Dahua, Detnov, Numens, TORK, Teletek
- Dahua HY-AA340R addressable gas detector, methane/LPG, NO/NC relay · 210,94 ₾/pcs
- Dahua HY-AF640R addressable CO detector, 0–1000 ppm, relay · 175,78 ₾/pcs
- Dahua HY-CA340R conventional natural gas/LPG detector, NO/NC relay · 210,94 ₾/pcs
- Dahua HY-CF640R conventional CO detector, 0–1000 ppm, relay · 175,78 ₾/pcs
- Dahua HY-GA40A natural gas alarm, 12 V DC, valve output · 84,38 ₾/pcs
- Dahua HY-GB40A LPG gas alarm, propane, 12 V DC, valve output · 84,38 ₾/pcs
- Dahua HY-GC20B standalone carbon monoxide alarm, LCD, 10-year battery · 112,50 ₾/pcs
- Dahua HY-GC21B-W2(868) wireless carbon monoxide alarm, LCD, 85 dB · 135,42 ₾/pcs
- Teletek SensoIRIS GAS addressable gas detector, CNG and LPG · 152,98 ₾/pcs
- Teletek AW-D125C conventional CO detector with siren and NO/NC relay, 20/28 V · 159,30 ₾/pcs
- Detnov DGD-600 natural gas leak detector, 24 V DC, 85 dB buzzer, relays · 358,00 ₾/pcs
- Detnov DMD-500 carbon monoxide (CO) detector, electrochemical cell, with deep base · 221,00 ₾/pcs
- Detnov DMDP-500 carbon monoxide (CO) detector, compact, anti-vandal · 243,00 ₾/pcs
- TORK Safe Home GA 20 gas leak detector with siren, mains plug · 65,00 ₾/pcs
Gas leak and carbon monoxide detectors. Most of them work on their own, without a fire panel: for a flat, a house, a boiler room or a café kitchen. For natural gas (methane): Dahua HY-GA40A, 12 V, with an output for a shut-off valve, and Detnov DGD-600 for 230 V or 24 V with an 85 dB buzzer and relays. For bottled gas (propane): Dahua HY-GB40A. For carbon monoxide (CO): the standalone Dahua HY-GC20B with a display and a 10-year battery, Numens 400-003 and Teletek AW-D125C with a built-in sounder and a relay — they need only a power supply.
The right detector depends on the gas. Natural gas is lighter than air and collects under the ceiling, so a methane detector goes on the wall 30 cm below the ceiling, near the cooker or the boiler. Bottled gas is heavier than air, so its detector goes 30 cm above the floor. Carbon monoxide appears when a boiler, a water heater or a stove has poor draught; its detector is fixed at breathing height or as the model's manual says. Models with a relay can close the gas with a valve or switch on the extractor. The category also holds detectors for a building's fire panel or an alarm hub: their pages say they work only with a panel and link to it. Delivery across Tbilisi.
Also searched as: gas detector, gas leak detector, gas alarm, carbon monoxide detector, CO detector, natural gas detector, LPG detector
Guides
- Which gas detector to choose: natural gas, bottled gas, with a valve
- How to protect your flat from fire, gas, carbon monoxide and floods
- Smoke alarm for a flat: stand-alone, battery-powered, no fitting
You may also need
Frequently asked questions
How does a natural gas detector differ from a carbon monoxide detector?
They sense different gases with different sensors. A natural gas (methane) detector catches a leak from a pipe or a cooker before the gas builds up. A carbon monoxide (CO) detector catches the product of incomplete burning, which has no smell. A home with a gas boiler or a water heater needs both.
Where should a gas detector go?
A methane detector goes on the wall 30 cm below the ceiling, 1–4 metres from the cooker or the boiler. A detector for bottled propane goes 30 cm above the floor. Do not fix it right above the cooker, by a window or by an extractor.
Can a detector shut the gas off by itself?
Yes, the models with a valve output or a relay: Dahua HY-GA40A and HY-GB40A, Detnov DGD-600. A solenoid shut-off valve on the gas pipe is wired to them.